1、,Manual of Implant Surgery種植手術(shù)指南,,1. Delayed Implantation 延期種植 - IMPLANTIUM 3810 (D-Ø3.8, L-10mm) - IMPLANTIUM 4310 (D-Ø4.3, L-10mm) * 2 stage (cover screw) 覆蓋螺絲 * 1 stage (healing abutment) 愈合基臺(tái)2.

2、 Immediate Implantation 即刻種植 - SuperLine 6010 (D-Ø6.0, L-10mm) * 1 stage (healing abutment) 愈合基臺(tái),,1. Delayed Implantation 延期種植 - IMPLANTIUM 3810 (D-Ø3.8, L-10mm) - IMPLANTIUM 4310 (D-Ø4.3, L-10m

3、m) * 2 stage (cover screw) 覆蓋螺絲 * 1 stage (healing abutment) 愈合基臺(tái),,,,,,Crestal Incision 牙槽脊切口,,,Flap Reflection 翻瓣,,,,,After Flap Reflection 翻瓣后,,Select Lindemann Guide Drill 選擇Lindemann導(dǎo)向鉆,,,3810 Fixture [

4、D.-Ø3.8, L.-10mm],Lindemann Guide Drill Lindemann導(dǎo)向鉆(1,000rpm with irrigation),,Surgical stent,,,,3810 Fixture [D.-Ø3.8, L.-10mm],Lindemann Guide Drill Lindemann導(dǎo)向鉆 (1,000rpm with irrigation),,Surgical

5、stent,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Lindemann Guide Drill Lindemann導(dǎo)向鉆 (1,000rpm with irrigation),,Surgical stent,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture

6、 [D.-Ø3.8, L.-10mm],Lindemann Guide Drill Lindemann導(dǎo)向鉆 (1,000rpm with irrigation),,Select Parallel Pin 選擇平行桿,,,,,Check the parallelism with adjacent tooth or implant 檢查就位方向,4310 Fixture [D.-Ø4.3, L.-10

7、mm],3810 Fixture [D.-Ø3.8, L.-10mm],,,,,Check the parallelism with adjacent tooth or implant檢查備孔的水平性,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,Select Lindemann First Drill Li

8、ndemann先鋒鉆,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [

9、D.-Ø3.8, L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,Select Depth Gauge 測(cè)深尺,,,,,,,,,Check the depth 確認(rèn)深度* Place the Depth gauge on the wall of osteotomy,4310 Fixture [D.-Ø4.

10、3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,Select Ø3.4 Final Drill 選擇Ø3.4成型鉆,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.4 Final Drill Ø3.4成型鉆

11、(1,000rpm with irrigation),,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.4 Final Drill Ø3.4成型鉆 (1,000rpm with irrigation),,Select Ø3.8 Final Drill 選擇3.8成型鉆,

12、,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.8 Final Drill Ø3.8成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-&#

13、216;3.8, L.-10mm],Ø3.8 Final Drill Ø3.8成型鉆 (1,000rpm with irrigation),,Select Ø3.8 Countersink 選擇Ø3.8皮質(zhì)骨成型鉆,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm

14、],Ø3.8 Countersink (1,000rpm with irrigation) Ø3.8皮質(zhì)骨成型鉆* If bone density is high, recommended to drill up to top line of laser mark,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-

15、6;3.8, L.-10mm],Ø3.8 Countersink (1,000rpm with irrigation) Ø3.8皮質(zhì)骨成型鉆* If bone density is high, recommended to drill up to top line of laser mark,,3810 Fixture [D.-Ø3.8, L.-10mm],Turn left the cap to

16、 open左轉(zhuǎn)打開瓶帽,Pull out the cap to open去除瓶帽,,*Connect adapter to implant hex firmly連接種植體,*Pull out implant carefully取出種植體,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-

17、Ø3.8, L.-10mm],Fixture [D.-Ø3.8, L.-10mm] Installation 植入Ø3.8種植體 * Top level of fixture be located 0.5mm below the crestal bone,,,,,,,,,,,,,,Fixture [D.-Ø3.8, L.-10mm] Installation 植入Ø3.8種植體

18、 * Top level of fixture be located 0.5mm below the crestal bone,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Select Path Pin 選擇定位桿,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],381

19、0 Fixture [D.-Ø3.8, L.-10mm],Check the parallelism with Path pin確認(rèn)種植體植入方向,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Check the parallelism with Path pin確認(rèn)種植體植入方向,,,,,

20、,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-&

21、#216;3.8, L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,Check the depth 確認(rèn)深度* Place the Depth gauge on the wall of osteotomy,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture

22、 [D.-Ø3.8, L.-10mm],,,,,,,,,,,,,,,Ø3.4 Final Drill Ø3.4成型鉆 (1,000rpm with irrigation),4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,,,,,,,,,,,,,,,4310 Fixture [D.-Ø

23、4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.4 Final Drill Ø3.4成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.8 Fi

24、nal Drill Ø3.8成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø3.8 Final Drill Ø3.8成型鉆 (1,000rpm with irrigation),,Select &

25、#216;4.3 Final Drill Ø4.3成型鉆,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø4.3 Final Drill Ø4.3成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,,,,,4310 Fix

26、ture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø4.3 Final Drill Ø4.3成型鉆 (1,000rpm with irrigation),,Select Ø4.3 Countersink Ø4.3皮質(zhì)骨成型鉆,,,,,,,,,,,,,,,,,,,,Ø4.3 Counters

27、ink (1,000rpm with irrigation) Ø4.3皮質(zhì)骨成型鉆* If bone density is high, recommended drilling up to top line of laser mark,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,,,,,,,,,,,,,,,,,

28、,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Ø4.3 Countersink (1,000rpm with irrigation) Ø4.3皮質(zhì)骨成型鉆* If bone density is high, recommended drilling up to top line of laser

29、 mark,,4310 Fixture [D.-Ø4.3, L.-10mm],Turn left the cap to open左轉(zhuǎn)打開瓶帽,Pull out the cap to open去除瓶帽,,*Connect adapter to implant hex firmly連接種植體,*Pull out implant carefully取出種植體,,,,,

30、,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Fixture [D.-Ø4.3, L.-10mm] Installation 植入Ø4.3種植體 * During insertion, 30~45N.cm at 20rpm is recommended 扭力30~

31、45N·cm,轉(zhuǎn)速20轉(zhuǎn)/分,,,,,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Fixture [D.-Ø4.3, L.-10mm] Installation 植入Ø4.3種植體 * During insertion, 30~45N.cm at 20rpm

32、 is recommended 扭力30~45N·cm,轉(zhuǎn)速20轉(zhuǎn)/分,,,Select Ratchet adapter and Ratchet扭力控制器用接頭和棘輪扳手,,,,,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Fixture [D.-Ø4.3, L.-1

33、0mm] Installation with Ratchet 用棘輪扳手植入種植體(Ø4.3)* Avoid applying 100N.cm torque or more,,,,,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Fixture [D.-Ø4.3, L.-

34、10mm] Installation with Ratchet 用棘輪扳手植入種植體(Ø4.3)* Avoid applying 100N.cm torque or more,,2 stage (cover screw) 二段式手術(shù)(覆蓋螺絲),,Select Hex Driver 六角扳手,,,,,,,,,,,,,,,,,,,,Cover screw installation with Hex Driver

35、 用六角扳手固定覆蓋螺絲,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Cover screw installation with Hex

36、Driver 用六角扳手固定覆蓋螺絲,,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Cover screw installation with Hex Driver 用六角扳手固定覆蓋螺絲,,,,Suture 縫合,,,,,,,,,,,,1 stage (healing abutme

37、nt)一段式手術(shù)(愈合基臺(tái)),,,,,,,,,,,,,,,,,,,,Healing abutment(Ø5.5M) installation with Hex Driver用六角扳手固定愈合基臺(tái) (Ø5.5M),4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],,,,,,,,,,,,,,,,,,,,4310 F

38、ixture [D.-Ø4.3, L.-10mm],3810 Fixture [D.-Ø3.8, L.-10mm],Healing abutment(Ø5.5M) installation with Hex Driver用六角扳手固定愈合基臺(tái) (Ø5.5M),,,,,,,,,,,,,,,,,,,,4310 Fixture [D.-Ø4.3, L.-10mm],3810 Fixtu

39、re [D.-Ø3.8, L.-10mm],Healing abutment(Ø5.5M) installation with Hex Driver用六角扳手固定愈合基臺(tái) (Ø5.5M),,,,Suture 縫合,,,,,,,,,,,,,2. Immediate Implantation 即刻種植 - SuperLine 6010 (D-Ø6.0, L-10mm) * 1s

40、tage (healing abutment),,,,,,Caries tooth extraction 拔除齲壞牙,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Lindemann Guide Drill Lindemann導(dǎo)向鉆 (1,000rpm with irrigation),,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm]

41、,Lindemann Guide Drill Lindemann導(dǎo)向鉆 (1,000rpm with irrigation),,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,,,,,,,,,,,,6010 Fixture [D.-Ø6.0,

42、L.-10mm],Lindemann First Drill Lindemann先鋒鉆 (1,000rpm with irrigation),,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø3.4 Final Drill Ø3.4成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,6010 Fixture [D

43、.-Ø6.0, L.-10mm],Ø3.4 Final Drill Ø3.4成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø3.8 Final Drill Ø3.8成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,

44、,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø3.8 Final Drill Ø3.8成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø4.3 Final Drill Ø4.3成型鉆 (1,000rpm with irrig

45、ation),,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø4.3 Final Drill Ø4.3成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø4.8 Final Drill Ø4.

46、8成型鉆 (1,000rpm with irrigation),,,,,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø4.8 Final Drill Ø4.8成型鉆 (1,000rpm with irrigation),Select Ø6.0 Countersink Ø6.0皮質(zhì)骨成型鉆,,,,,,,,,,,,,

47、,,,,,,,,,,,Ø6.0 Countersink Ø6.0皮質(zhì)骨成型鉆(1,000rpm with irrigation),6010 Fixture [D.-Ø6.0, L.-10mm],,,,,,,,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Ø6.0 Countersink Ø6.0皮質(zhì)骨成型鉆

48、(1,000rpm with irrigation),,,,,,,,,,,,,,,,,,,,,,,,,,Fixture [D.-Ø6.0, L.-10mm] Installation 植入Ø6.0種植體 * Top level of fixture be located 0.5mm below the crestal bone,6010 Fixture [D.-Ø6.0, L.-10mm],,,,

49、,,,,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Fixture [D.-Ø6.0, L.-10mm] Installation 植入Ø6.0種植體 * Top level of fixture be located 0.5mm below the crestal bone,,,,,,,,,,,,,,,,,,,,,,,,,,Healing a

50、butment (Ø7.0M) installation with Hex Driver用六角扳手固定愈合基臺(tái)(Ø7.0M),6010 Fixture [D.-Ø6.0, L.-10mm],,,,,,,,,,,,,,,,,,,,,,,,,,6010 Fixture [D.-Ø6.0, L.-10mm],Healing abutment (Ø7.0M) installation wi

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 眾賞文庫(kù)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論